Independent audit gates and preserved limitations log
Search all 56 independent G1-G4 audit gates (12 tracks + CRO verifier + GALENOS Core) alongside every preserved boundary, HOLD, and negative finding.
| Track & ID | Status | Specification / preserved finding | Observed receipt |
|---|---|---|---|
| Rare-disease genomics / G1 | Pass | Raw SHA-256 provenance & disjoint 20-dev / 20-blind gene lockVerified SHA-256 hashes of all 12 raw inputs against protocol.json and split-lock.json, and independently confirmed 20 development genes (n=2,797) and 20 disjoint blind held-out genes (n=3,214) with zero gene overlap and zero truth self-lookup. | Raw verifier output (4 values)files=12/12, devGenes=20(n=2797), blindGenes=20(n=3214), overlap=0 |
| Rare-disease genomics / G2 | Pass | Tavtigian Bayesian law & 2,500-mutation VerifiedLedger interceptionRecomputed Tavtigian log10(OP) = pts * log10(350)/8, verified Bayesian posterior mass normalization, and independently re-audited all 2,500 adversarial fault mutations across GoF PVS1, unphased PM3, BA1+PVS1 conflict, tampered SHA-256, and unindexed PMIDs. | Raw verifier output (4 values)advIntercepted=2500/2500, gofPvs1Fires=0, maxTavResid=4.94e-07, maxPostResid=1.80e-05 |
| Rare-disease genomics / G3 | Pass | Blind 20-gene benchmark & live 10,377-Phenopacket cohort replayIndependently recomputed Mann-Whitney AUROC on the 3,214 blind-gene ClinGen variants, Top-5 diagnostic recall on the 120 blind VCFxHPO cases, and live Top-5/Top-10 recall across both the n=1,874 temporal test slice and n=10278 solved Phenopacket Store. | Raw verifier output (3 values)blindAUROC=0.9838 (vs 0.9383), blindTop5=100.00%, phenopacket1874Top5=10.51% |
| Rare-disease genomics / G4 | Pass | ISO 14971 safety HOLD disclosure and empty human signatureVerified that VUS and gain-of-function cases are disclosed as HOLD, that each case reports its metrics together with the live input it was run on, and that the human auditor signature stays empty until a reviewer signs. | Raw verifier output (4 values)solverFree=True, holdCase=True, hygieneIssues=0, humanSignature=None |
Rare-disease genomics / RARE19-F1 | Negative | 2022 temporal Phenopacket split reports 10.51% all-case vs 28.51% G2P-indexed Top-5 (83.25% under HPO v2026-09-01)Evaluating 10377 clinical phenopackets in phenopackets.zip with Bayesian-shrunk Symmetric BMA on HPO v2022-12-15 achieves 33.6% Top-5 across 10278 solved cases, and 10.51% overall (28.51% among 691 G2P-indexed cases) on the n=1874 2024-2025 cutoff cohort because 1183 cases involve newly published disease genes absent from the 2022 G2P index (0 zero-IC). Separate non-leakage-free HPO v2026-09-01 reanalysis recovers 83.25% Top-5 (86.2% indexed), while joint VCFxHPO reaches 100.0% on the 20 blind genes. | |
Rare-disease genomics / RARE19-F2 | Hold | Gain-of-function non-LoF genes suppress PVS1 and route missense VUS to clinical HOLDAcross non-loss-of-function genes (GFAP, MYH7, MYOC), automatic PVS1 invocation is blocked (0 false PVS1 fires across all 8,667 ClinGen variants), and 1636 blind-gene VUS variants remain held at Uncertain significance pending PS3/BS3 functional assays. | |
Rare-disease genomics / RARE19-F3 | Boundary | VerifiedLedger blocks 2500/2500 injected ACMG and provenance mutationsIndependent solver-free replay verified 100% blocking across 500 GoF PVS1 misuses, 500 unphased singleton/in-cis PM3 claims, 500 BA1+pathogenic rule conflicts, 500 SHA-256 ledger digest tamperings, and 500 fabricated unindexed PMIDs. | |
| Cardiac hemodynamics / G1 | Pass | MIMIC-IV SHA-256 provenance, temporal split & zero raw ID leakageVerified SHA-256 hashes of all 5 gzipped MIMIC-IV Demo tables, confirmed SpO2/CVP/ABP/HR extraction across strictly chronological early vs future windows, and scanned output JSON against all raw subject_id/stay_id/hadm_id values (0 leaks). | Raw verifier output (6 values)files=5/5, stays=134, subjects=98, spo2Stays=134, cvpStays=23, leakedIds=0 |
| Cardiac hemodynamics / G2 | Pass | LV/RV RK4 conservation (< 1e-6 mL/beat) & dt=1.0 ms vs 0.5 ms convergenceIndependently re-integrated the 6-compartment LV+RV elastance ODE in pure Python across 12 checkpoints at dt=1.0 ms and dt=0.5 ms, confirming < 1e-6 mL/beat volume conservation, step-halving stability, and physiological vasodilator/inotrope stroke volume response. | Raw verifier output (3 values)maxVolDriftBeat=2.10e-12 mL, dt1vs05Diff=0.0001 mmHg, reintErr1ms=2.00e-04 mmHg |
| Cardiac hemodynamics / G3 | Pass | Held-out hemodynamic MAE/RMSE & instability AUROC replayIndependently recomputed baseline inverse-fit MAE, held-out MAP/PP MAE & RMSE, and Mann-Whitney AUROC with 2000 subject-cluster bootstrap draws against the early-window persistence baseline. All forecasts were independently replayed using inputs available by ICU admission + 6 hours. | Raw verifier output (3 values)metricIntegrityVerified=true; summary=AUROC=0.7954 vs 0.6498, MAP MAE=5.78 vs 6.76 mmHg, PP MAE=8.70 vs 8.06 mmHg; unmetPerformanceTargets: [] |
| Cardiac hemodynamics / G4 | Pass | ASME V&V 40 out-of-domain safety HOLD and empty human signatureVerified the physiological out-of-domain HOLD case, that each case records its metrics with the live input it was run on, and an empty human auditor signature. | Raw verifier output (4 values)solverFree=True, holdCase=True, hygieneIssues=0, humanSignature=None |
Cardiac hemodynamics / TWIN32-F1 | Boundary | Baroreflex forecast beats MAP persistence, while pulse pressure reflects unmodeled cuff & therapy shiftsCentral-aortic pulse-amplification inverse fitting reduces early MAP MAE to 0.84 mmHg, and carotid baroreflex feedback lowers 6-24 h held-out MAP MAE to 5.78 mmHg (RMSE 7.68 mmHg vs persistence MAE 6.76 / RMSE 8.98 mmHg). Held-out brachial pulse pressure MAE remains 8.70 vs 8.06 mmHg because post-cutoff medication changes are not inputs. | |
Cardiac hemodynamics / TWIN32-F2 | Hold | Out-of-domain tachyarrhythmia, severe hypoxemia & cardiogenic shock route to HOLDAt HR > 155 bpm, E_max_lv < 0.50 mmHg/mL, SpO2 < 85%, or MAP < 42 mmHg, diastolic filling truncation and right-left ventricular interdependence require invasive Swan-Ganz or mechanical circulatory support evaluation; automated fluid titration is suspended via HOLD. | |
Cardiac hemodynamics / TWIN32-F3 | Negative | 0D lumped compartmental ODE cannot localize regional coronary stenosis or valve regurgitation jetsWhile 6-compartment LV+RV RK4 integration preserves total blood volume to 2.10e-12 mL/beat (< 1e-6 mL/beat) and converges within 0.0001 mmHg between dt=1.0 ms and dt=0.5 ms, spatial transvalvular velocity jets and regional wall-motion defects require 3D echo/CFD. | |
| Musculoskeletal imaging / G1 | Pass | 3D NIfTI header & UCI orthopedic SHA-256 provenance verificationRe-hashed CT_Abdo.nii.gz and vertebral_column.zip, unpacked the 348-byte NIfTI-1 binary header in pure Python stdlib to confirm 255x178x256 voxels and spacing, and verified all 310 5-fold stratified out-of-fold records. | Raw verifier output (5 values)ctShape=[255, 178, 256], voxels=11619840, uciPatients=310, ctSubjects=1, cvFolds=5 |
| Musculoskeletal imaging / G2 | Pass | Beer-Lambert attenuation law & 310-patient PI = PT + SS identityIndependently verified I = exp(-tau) across all 63 3D CT Beer-Lambert DRR projections and re-checked |PI - (PT + SS)| <= 0.0001 deg across all 310 raw ARFF records in vertebral_column.zip. | Raw verifier output (3 values)drrCount=63, maxBeerLambertResid=4.80e-07, maxPiResid=0.000000 deg |
| Musculoskeletal imaging / G3 | Pass | UCI 5-fold OOF AUROC & 3D CT->DRR pose recovery MAE replayIndependently recomputed Mann-Whitney AUROC + 600-replicate bootstrap 95% CI on all 310 out-of-fold predictions and verified pose-corrected vs naive 2D DRR MAE across accepted poses. | Raw verifier output (1 values)OOF AUROC=0.9258 (vs 0.7229), CT->DRR MAE=0.333 vs Naive=1.308 deg |
| Musculoskeletal imaging / G4 | Pass | Malrotation and missing PixelSpacing safety HOLDs and empty human signatureVerified 100% HOLD interception on >12 deg malrotation and missing DICOM PixelSpacing, normalized 0..100 viewport landmarks, case metrics recorded with their live inputs, and an empty human auditor signature. | Raw verifier output (4 values)solverFree=True, malrotHold=100%, missingSpacingHold=100%, hygieneIssues=0 |
Musculoskeletal imaging / XRAY12-F1 | Negative | Real 3D human CT lumbar lordosis induces up to 4.09 deg 2D radiographic angle distortion under axial yawForward Beer-Lambert ray-casting of CT_Abdo.nii.gz (255x178x256 voxels) across -15 to +15 deg yaw shows that anterior lumbar lordosis projects laterally as 2D coronal angle distortion (all-pose naive MAE 1.308 deg), whereas 3D pose-offset recovery restores MAE to 0.333 deg (RMSE 0.415 deg). | |
Musculoskeletal imaging / XRAY12-F2 | Hold | Malrotation (> 12 deg) & missing DICOM PixelSpacing (0028,0030) automatically trigger HOLDAll extreme malrotations >= 13.5 deg (100.0% recall) and all radiographs lacking calibrated DICOM PixelSpacing metadata (100.0% recall) are intercepted and held from surgical planning until repeat AP imaging or calibration is supplied. | |
Musculoskeletal imaging / XRAY12-F3 | Boundary | 2D planar radiographs require biplanar or 3D CT confirmation for transverse pedicle screw trajectoriesAcross all 310 UCI orthopedic patients, spinopelvic identity PI = PT + SS holds within 0.00 deg and 5-fold stratified CV achieves AUROC 0.9258 (vs 0.7229 for PI alone), but axial vertebral rotation and pedicle breach margins still require 3D CT. | |
| Intrapartum fetal monitoring / G1 | Pass | 552/552 CTU-UHB header & 4 Hz waveform SHA-256 + split lockVerified all 552 .hea clinical headers and all 552 Format-16 4 Hz .dat binary waveforms on disk with zero train/val/test delivery overlap. | Raw verifier output (4 values)552 .hea + 552 .dat verified; split train=342, val=74, test=136; errors=0 |
| Intrapartum fetal monitoring / G2 | Pass | Forbidden Outcome/Covariate exclusion & uteroplacental O2 conservationOutcome labels, stage-II timing and six untimed clinical-event covariates are excluded; frozen inference matches all stored predictions and RK4 O2 conservation is checked (<1e-6). | Raw verifier output (4 values)leaked_features=0; max_O2_residual=2.50e-07; ODE_pH(normal=7.3011, tachy=6.85, preeclampsia=6.85) |
| Intrapartum fetal monitoring / G3 | Pass | Solver-free locked-test umbilical acidemia AUROC & 4 Hz Spearman auditIndependently recomputed eligible test AUROC for pH < 7.15 and pH < 7.10 versus maternal-age baseline, plus 493-record deceleration-area vs cord pH Spearman rho under identical fitting/evaluation/serving rules. | Raw verifier output (3 values)test_QC_n=124 AUROC(pH<7.15)=0.7582 [0.6264, 0.8724], AUROC(pH<7.10)=0.8385, age_base=0.4970, rho_eligible=-0.3305 |
| Intrapartum fetal monitoring / G4 | Pass | >35% Doppler signal-dropout HOLD gate & statutory OB/GYN boundariesIdentical input and quality rules abstained on 59/552 records (12/136 in test). Missing covariates, constant channels and unusable signals receive no score during fitting, evaluation or serving. | Raw verifier output (2 values)cohort_HOLD=59/552 (10.7%, 95% CI [8.4%, 13.5%]); test_HOLD=12/136 |
Intrapartum fetal monitoring / F-13-2-ZERO-POSTHOC-LEAKAGE | Boundary | Four stable covariates and record-end 4 Hz waveform classificationExcluding outcome labels, delivery-stage fields and six untimed clinical-event covariates yields record-end test AUROC 0.7582 for pH < 7.15 and 0.8385 for the secondary endpoint pH < 7.10 across 124 QC-passing deliveries (versus antenatal maternal-age baseline 0.4970). | |
Intrapartum fetal monitoring / F-13-2-RECORD-UNIT-BOUNDARY | Boundary | Delivery-record unit and retrospective classification scopeThe split and bootstrap unit is one CTG delivery record. Maternal linkage across different deliveries is unavailable. The study does not establish mother-level independence, prospective lead time, or calibrated individual clinical risk. | |
Intrapartum fetal monitoring / F-13-2-TRANSDUCER-DROPOUT-SAFETY | Hold | Severe Doppler signal loss (>35%) masks late decelerations without mandatory HOLDThe identical fitting/evaluation/serving contract abstains on 59/552 records. No normal default features or probability are manufactured for missing covariates, constant channels or unusable signals. | |
Intrapartum fetal monitoring / F-13-2-STATUTORY-IRB-COI | External | Domestic delivery-ward IRB chart concordance and internal conflict-of-interest disclosureCommercial MFDS Obstetric SaMD submission requires multi-center Korean delivery-ward IRB chart concordance, IEC 62366-1 alarm-fatigue human-factors validation; under RISCON Labs internal rules, specialist advisory review also follows a written conflict-of-interest disclosure. | |
| Ambulatory ECG / G1 | Pass | 48/48 Format-212 binary waveforms SHA-256 & AAMI DS1/DS2 patient lockVerified all 144 MIT-BIH files (48 .hea + 48 .atr + 48 Format-212 .dat) on disk with zero initial ADC header mismatches and strict 22-vs-22 patient-disjoint DS1/DS2 partitioning. | Raw verifier output (3 values)144/144 files verified; 48/48 .dat ADC init mismatches=0; DS1=22 patients, DS2=22 patients |
| Ambulatory ECG / G2 | Pass | 3D cardiac dipole limit-cycle stability & SNR < 6 dB abstention lawConfirmed RK4 unit-circle radial drift (<1e-3), physiological R-peak voltage, and independent signal-to-noise recomputation enforcing automatic HOLD at 3.8 dB. | Raw verifier output (3 values)clean_SNR=18.60 dB (PASS), motion_SNR=3.80 dB (HOLD), max_radial_drift=0.00e+00 |
| Ambulatory ECG / G3 | Pass | Blind 48-record Pan-Tompkins QRS & DS2 ventricular ectopy auditIndependently verified blind Pan-Tompkins QRS sensitivity/PPV across 109,966 beats (+-150 ms) and blind DS2 330-epoch AUROC + 49,689-beat VEB sensitivity/specificity. | Raw verifier output (3 values)48-rec QRS Sens=99.33%, PPV=99.61% (n=109966); DS2 epoch AUROC=0.9781 vs RR_base=0.8625; DS2 beat Sens=96.47%, Spec=98.78% |
| Ambulatory ECG / G4 | Pass | Electrode detachment HOLD, AAMI paced quarantine & MFDS hardware gateVerified SNR < 6.0 dB automatic abstention, quarantined 4 AAMI-excluded paced records (102, 104, 107, 217), and preserved domestic patch impedance bench requirements. | Raw verifier output (3 values)paced_quarantined=4; hold_cases=1; flat_metric_errors=0 |
Ambulatory ECG / F-11-36-BLIND-QRS-BOUNDARY | Boundary | Tall peaked P waves (record 108) and ventricular flutter (record 207) challenge single-band QRS detectionAcross all 48 raw 360 Hz records (109966 beats), blind Pan-Tompkins achieves 99.33% sensitivity (99.28%-99.37%) and 99.61% PPV, with residual false alarms concentrated in giant P-wave noise bursts and non-QRS ventricular flutter oscillations. | |
Ambulatory ECG / F-11-36-PATCH-SNR-ABSTENTION | Hold | Skeletal EMG & electrode pop below 6.0 dB SNR require mandatory patch HOLDWhen dry/hydrogel patch detachment lowers SNR to 3.8 dB (< 6.0 dB), bandpass energy mimics polymorphic ventricular tachycardia; automatic HOLD suppresses false bedside alarms until skin contact recovers. | |
Ambulatory ECG / F-11-36-MFDS-PATCH-BENCH-EXT | External | AAMI paced quarantine & domestic wearable patch impedance front-end trial gateFollowing ANSI/AAMI EC57, 4 paced records (102, 104, 107, 217) remain quarantined from sinus/VEB scoring; MFDS Class II/III SaMD clearance requires hardware lead-off impedance coupling and Korean ambulatory Holter clinical validation. | |
| Sepsis and ARDS ventilation / G1 | Pass | MIMIC-IV 7-table SHA-256, subject split & <=24h real trajectory lockVerified all 7 MIMIC-IV Demo v2.2 .csv.gz tables on disk, zero subject crossing across 140 stays, zero hand-typed arrays, and strict 0 <= offset <= 24.0h timestamps. | Raw verifier output (4 values)train_subjects=50, test_subjects=50 (stays=66); max_offset=23.98h (<=24.0h); excluded_post24_chart=63924 |
| Sepsis and ARDS ventilation / G2 | Pass | 3-compartment West lung O2 flux conservation & delta P safety lawVerified CaO2 = (1 - Qs/Qt)*Cc'O2 + (Qs/Qt)*CvO2 to <1e-5 mL/dL via Severinghaus-Hill dissociation and confirmed Delta P > 15 cmH2O barotrauma detection on real stay states. | Raw verifier output (3 values)max_O2_flux_residual=3.92e-06 mL/dL; barotrauma_states_verified=1; vq_states=4 |
| Sepsis and ARDS ventilation / G3 | Pass | Solver-free subject-locked ICU deterioration AUROC & calibration auditIndependently recomputed holdout ICU deterioration AUROC, 95% bootstrap CI, Brier score, and ECE without solver imports, confirming gain over admission shock-index. | Raw verifier output (3 values)holdout_AUROC=0.8079 [0.6723, 0.9197] vs shock_index_base=0.6749; Brier=0.1459, ECE=0.0962 |
| Sepsis and ARDS ventilation / G4 | Pass | Barotrauma (delta P > 15 cmH2O) & missing-ABG HOLD gates + KR ICU gateVerified automatic HOLD gates on both real Delta P > 15 cmH2O barotrauma stays and ventilated stays lacking 24h arterial PaO2, plus KR CDI / HL7 FHIR requirements. | Raw verifier output (3 values)cohort_barotrauma_stays=11, missing_ABG_stays=1; workbench_HOLD_cases=2 |
Sepsis and ARDS ventilation / F-11-61-REAL-COHORT-SIZE-BOUNDARY | Boundary | MIMIC-IV Demo sample size (100 subjects, 140 stays) widens holdout confidence intervalAcross 66 subject-disjoint holdout ICU stays, coupling West V/Q shunt and driving pressure with first-24h organ-dysfunction labs reaches AUROC 0.8079 (95% CI 0.6723-0.9197) versus shock-index 0.6749; tighter CIs require multi-thousand-stay hospital cohorts. | |
Sepsis and ARDS ventilation / F-11-61-BAROTRAUMA-AND-ABG-HOLDS | Hold | Dual bedside safety interlocks: Delta P > 15 cmH2O barotrauma & missing-ABG SpO2 plateauIn real MIMIC-IV ventilator series, 11 stays exceed 15 cmH2O driving pressure and 1 ventilated stays lack 24h arterial PaO2 at SpO2 >= 97%; both states trigger mandatory HOLD to block unsafe PEEP escalation or ill-posed shunt inversion. | |
Sepsis and ARDS ventilation / F-11-61-KR-ICU-FHIR-CALIBRATION | External | Domestic tertiary ICU external recalibration & KR CDI / HL7 FHIR streaming gateBecause antibiotic timing, ventilator weaning protocols, and ARDS etiology differ between US Beth Israel Deaconess and Korean tertiary ICUs, domestic multi-center IRB recalibration and HL7 FHIR R4 bedside integration remain external gates. | |
| Aortic dissection flow / G1 | Pass | Public 3D CTA & 4D-flow provenance & S-PUB stage lockVerified SHA-256 and internal structures of all 5 Stanford VMR TBAD 3D CTA/4D-Flow ZIPs, all 60 CHUV AortaSeg-60 NIfTI masks (352-byte headers), and MIMIC-IV tables; 0 Korean IRB prospective cases disclosed. | Raw verifier output (4 values)evidenceStage=S-PUB; koreanHospitalProspectiveCtaCount=0; public4dFlowCfdModelCount=5; publicCta3dMaskCount=60 |
| Aortic dissection flow / G2 | Pass | Stdlib ODE re-integration, Stanford 0160 4D-flow & mass continuity (< 1e-5 mL)Re-integrated 8 synthetic checkpoints and Stanford 0160 measured 4D-Flow waveform in stdlib, confirming cycle continuity < 1e-5 mL/beat and TEVAR diastolic decompression. | Raw verifier output (4 values)maxCheckpointRk4DiffMmHg=0; maxContinuityResidualMl=1.17e-06; paradoxCasePostDiastolicDpMmHg=-38.19; paradoxCasePreDiastolicDpMmHg=17.76 |
| Aortic dissection flow / G3 | Pass | 360-morphology RK4 convergence RMSE & bootstrap 95% CI recomputationIndependently recomputed mean RK4 (1.0 vs 0.5 ms) RMSE, 600-replicate bootstrap 95% CI, Euler 2.0 ms baseline RMSE, and virtual TEVAR pulse-pressure reduction. | Raw verifier output (4 values)eulerBaselineRmseMmHg=0.4632; rk4ConvergenceCi95: [4.40e-07, 5.20e-07]; rk4ConvergenceRmseMmHg=4.80e-07; smallDistalTearExcessMmHg=15.85 |
| Aortic dissection flow / G4 | Pass | Visceral hypoperfusion, Laplace tension HOLD & zero prospective IRB claimsConfirmed mandatory HOLD escalation on visceral false-lumen hypoperfusion and outer-wall tension > 220 kPa, Stanford 0160 PASS verification, and an empty human auditor signature. | Raw verifier output (4 values)humanAuditorSignature=null; stanford0160Verdict=PASS; visceralHoldTriggered=true; wallTensionHoldCount=49 |
Aortic dissection flow / AORTA-SPUB-01 | Pass | Calibrated on 55 unique (60 cohort entries) 3D CT masks & 5 Stanford VMR modelsStage S-PUB anchors aortic diameter distributions via 3D Euclidean distance transform maximal inscribed sphere on 60 AortaSeg-60 entries (55 unique SHA-256 CT segmentations: Young mean 29.6 mm, Dissec 39.7 mm, Anev 52.1 mm) and runs across 360 derived morphologies bounded by 5 Stanford VMR models (0160_H_AO_AOD measured 4D-Flow MRI inflow at 477.93 mL/s peak, 109/56 mmHg cuff, plus 0221..0224 tear variants). | |
Aortic dissection flow / AORTA-HOLD-02 | Hold | Visceral false-lumen origin & outer-wall tension (> 220 kPa) trigger automatic HOLDProximal stent sealing leaves visceral branches hypoperfused (< 50% baseline flow) when distal re-entry is narrow; likewise Laplace outer-wall tension > 220 kPa escalates to HOLD pending fenestrated surgical review. | |
Aortic dissection flow / AORTA-IRB-03 | External | Zero prospective Korean IRB clinical outcome trials executed (0 cases)While public 3D CT morphology and Stanford 4D-Flow MRI physics are verified at S-PUB, prospective Korean clinical outcome follow-up and full 3D FSI ASME V&V 40 MFDS clearance remain unexecuted (0 cases, zero synthetic AUROC). | |
| IPF lung transcriptome / G1 | Pass | GEO cross-platform provenance, Train/Val/Test disjointness & de-identificationVerified SHA-256 digests of GSE32537 (n=217, GPL6244), GSE24206 (n=23, GPL570), and 7,819-probe bridge; confirmed disjoint GSE32537 indices (130/33/54) and 0 leaked raw GSM IDs. | Raw verifier output (3 values)externalSamples=23; sharedProbeCount=7819; splitSizes: 130, 33, 54 |
| IPF lung transcriptome / G2 | Pass | Unbiased train-only differential expression & Gaussian-Copula DP-synth lawIndependently streamed raw GSE32537 train split (n=130) to verify Welch t-stats across all 32 selected probes (FNDC1, SFRP2, MDK, max drift 4.96e-07, cutoff |t| > 12.58) and verified Gaussian-copula DP-Synth MIA <= 0.55 (observed max 0.5451). | Raw verifier output (6 values)fdrLt0p01Count=3841; kSelected=32; maxLog2FcDrift=5.00e-07; maxMiaAuroc=0.5451; maxWelchTDrift=5.00e-07; totalSharedProbesEvaluated=7819 |
| IPF lung transcriptome / G3 | Pass | Solver-free external GSE24206 & locked GSE32537 AUROC + DP TSTR recomputationRecomputed external GSE24206 AUROC = 0.9902 (95% CI 0.9412..1.0000 vs MUC5B 0.8922), locked GSE32537 holdout AUROC = 1.0000, and epsilon=2.0 DP-Synth external TSTR AUROC = 0.9412. | Raw verifier output (9 values)dpEps2ExternalTstrAuroc=0.9412; externalBrier=0.046; externalEce=0.0501; externalGse24206Auroc=0.9902; externalGse24206Ci95: [0.9412, 1]; externalGse24206DonorClusterCi95: [0.9464, 1]; externalMuc5bBaselineAuroc=0.8922; externalSubjectCount=17; lockedGse32537TestAuroc=1 |
| IPF lung transcriptome / G4 | Pass | Cellular NSIP borderline abstention & cross-platform batch drift HOLD gateVerified mandatory HOLD on indeterminate cellular NSIP (0.35..0.65 band) and unharmonized platform batch z-drift (mean |z| = 2.6119 > 2.00), with humanAuditorSignature = None. | Raw verifier output (4 values)batchDriftHoldActive=true; humanAuditorSignature=null; nsipHoldActive=true; rawUnharmonizedMeanAbsZ=2.6119 |
IPF lung transcriptome / OMICS-COHORT-01 | External | External cohort GSE24206 has modest sample size (n=23, 95% CI width ~0.04) & bulk biopsy scopeUnbiased discovery across all 7,819 shared probes inside GSE32537 train (n=130) achieves AUROC 0.9902 on external GSE24206, but GSE24206 comprises n=23 bulk lung samples (17 IPF, 6 healthy controls from 17 donors); prospective multicenter RNA-seq and spatial single-cell validation remain external. | |
IPF lung transcriptome / OMICS-HOLD-02 | Hold | Raw GPL6244-to-GPL570 batch shift (mean |z| > 2.00) & cellular NSIP overlap trigger mandatory HOLDApplying GPL6244 raw reference scale directly to unharmonized GPL570 yields mean |z| = 2.6119 (> 2.00), blocking uncalibrated inference; cellular NSIP biopsies in the 0.35..0.65 probability band are likewise held for HRCT/pathology review. | |
IPF lung transcriptome / OMICS-PRIVACY-03 | External | Gaussian-Copula DP-synth bounds transcriptome MIA <= 0.55, while raw clinical biopsy sharing requires IRB/DRBAt epsilon = 2.0, train-only Gaussian-copula synthesis preserves external TSTR AUROC 0.9412 with MIA AUROC 0.5290, yet clinical multi-omics data release still requires institutional IRB and Data Review Board sign-off. | |
| Dementia brain MRI / G1 | Pass | Exact manifest subject-hash partition (90/29/31) & real 3D NIfTI SHA-256 provenanceVerified SHA-256 digests of OASIS-2 XLSX, manifests/16-2-16-3-oasis2.tsv, and 3 real human brain NIfTI volumes (chris_t1, chris_t2, mni152); proved exact 1-to-1 equality across all 150 subjects and 373 longitudinal visits (234/66/73) with 0 crossing subjects and 0 leaked OAS2 IDs. | Raw verifier output (6 values)crossingSubjects=0; niftiVolumesVerified=3; subjectSplitCounts: 90, 29, 31; visitPartitionCounts: (test=73, train=234, validation=66) |
| Dementia brain MRI / G2 | Pass | Pure-stdlib 2D complex k-space susceptibility blooming & 3.0T B1+ harmonization auditIndependently verified 2D DFT Parseval conservation (rel err 1.09e-15), inverse-FFT patch reconstruction (drift 6.82e-07), 3.0T/1.5T T2*-GRE blooming expansion (386.4 vs 279.6 mm2, 1.382x), and 95.94% 3.0T nWBV RMSE reduction. | Raw verifier output (7 values)bloomingArea15TMm2=279.56; bloomingArea30TMm2=386.43; bloomingRatio3TTo15T=1.3823; driftReductionPct=95.94; kSpaceMaxParsevalRelErr=0; kSpaceMaxReconDrift=6.80e-07; maxSlopeDriftPctYr=3.40e-05 |
| Dementia brain MRI / G3 | Pass | Concurrent CDR classification and subject-cluster CI (73 visits / 31 subjects)Recomputed locked test visit AUROC = 0.8989 (95% CI 0.7968..0.9706) vs Chronological Age-only baseline 0.4054, terminal subject AUROC = 0.8917, and Brier = 0.1509; 2000 subject-cluster draws, fixed model, no MMSE or future Group labels. | Raw verifier output (27 values)ageOnlyBaselineAuroc=0.4054; clusterUncertainty: (ci95=0.7968, 0.9706, confidenceLevel=0.95, estimand=visit_weighted_auroc_of_fixed_model, method=unstratified-subject-cluster-percentile-v1, negativeVisits=39, positiveVisits=34, quantileMethod=linear_(B-1)*q, replicatesAttempted=2000, replicatesValid=2000, resampleIndicesSha256=264264498353bca1f4b3301e31faea6441576733d40adfc057fdf262c0c84dd3, resampleUnit=subject, seed=20261115, singleClassDraws=0, stratification=none, subjectCount=31, subjectSizesSha256=73bc1bb092e8a7bbe12945a933e38858d2405de65c36f88effab69c804a34ec0, visitCount=73, withinSubjectPolicy=retain_all_visits_with_subject_multiplicity); lockedTestAuprc=0.9011; lockedTestBrier=0.1509; lockedTestEce=0.1239; lockedTestSubjectAuroc=0.8917; lockedTestVisitAuroc=0.8989; lockedTestVisitCi95: [0.7968, 0.9706]; metricIntegrityVerified=true; unmetPerformanceTargets: [] |
| Dementia brain MRI / G4 | Pass | Injected microbleed simulation HOLD and research classification HOLDVerified automatic HOLD on ARIA-H microbleed count (6 >= 5 threshold) and uncertain CDR 0.5 triage (0.35..0.65 band, 14 test visits held), with humanAuditorSignature = None. | Raw verifier output (5 values)ariaHHoldActive=true; cdr05UncertainHoldActive=true; cdr05UncertainHoldTestVisits=14; detectedAriaHMicrobleeds=6; humanAuditorSignature=null |
Dementia brain MRI / DEMENTIA-MODALITY-01 | External | Concurrent CDR classification from measured morphometry; no future progression validationFixed logistic model AUROC 0.8989 on 73 visits from 31 held-out subjects. Inputs are premeasured nWBV/eTIV/ASF and demographics; this is not raw MRI segmentation. CDR and Group are never inference inputs, and future Converted group labels are excluded from training targets. | |
Dementia brain MRI / DEMENTIA-UNCERTAINTY-02 | Hold | 31 independent test subjects; 2000 subject-cluster bootstrap drawsVisit-weighted AUROC CI 0.796831..0.970614 retains all visits within each sampled subject. AUPRC 0.901125, Brier 0.150923, ECE 0.123905. This conditional fixed-model interval excludes model-training and external-population uncertainty. | |
Dementia brain MRI / DEMENTIA-SIMULATION-03 | External | Real brain templates with synthetic lesions and scanner shiftsThe k-space test injects six microbleeds into a brain template; it does not detect naturally occurring patient ARIA. Blooming ratio 1.382 and shift reduction 95.9% verify the specified simulation only. No drug eligibility or ARIA-risk probability is produced. | |
| Pre-operative safety check / G1 | Pass | SNUH VitalDB 2,400-stay provenance, Cholec80 lock & zero raw identifier checkVerified S-PUB anchoring on 6388 SNUH VitalDB surgical stays (2,400 distinct pseudonymous caseHashes, 8 real pre-op acute creatinine surges, zero raw subject identifiers, zero prospective OR interlock trials) and the Cholec80 split manifest (40/8/32, 0 overlap). | Raw verifier output (6 values)evidenceStage=S-PUB; lockedTestVideosCovered=32; manifestSha256=5bcd91385542801389843f00124c1b862b886a1ac2c856cd256271b370fd0fc4; prospectiveLiveOrInterlockTrials=0; vitaldbDistinctStaysAnchored=2400; vitaldbLongitudinalAcuteCrVerified=8 |
| Pre-operative safety check / G2 | Pass | HL7 FHIR R4, DICOM (0020,0060)/(0008,103E) & CKD-EPI 2021 eGFR rule verificationIndependently recomputed CKD-EPI 2021 race-free eGFR across all 2,400 scenarios and verified 0 silent passes across 800 wrong-site/wrong-patient/spinal-level faults and 32 Cholec80 test video IDs with structured sponge-count fault records. | Raw verifier output (4 values)ckdEpi2021Mismatches=0; renalWashoutSilentPasses=0; spongeCountSilentPasses=0; wrongSiteOrPatientSilentPasses=0 |
| Pre-operative safety check / G3 | Pass | Fault-injected safety mismatch interception accuracy & Wilson 95% CIRecomputed interception accuracy = 0.978333 (2348/2400, 95% Wilson CI [0.971699, 0.983439] >= 0.95 internal pre-set target) vs 0.587917 surface string-match baseline. | Raw verifier output (7 values)baselineAccuracy=0.5879; fn=14; fp=38; interceptionAccuracy=0.9783; tn=1162; tp=1186; wilson95: [0.9717, 0.9834] |
| Pre-operative safety check / G4 | Pass | Missing-consent-signature HOLD gate & stale-lab boundary disclosureVerified 90/90 (1.0) missing-signature consents routed to HOLD, 128 total bedside HOLDs, and 14 stale-creatinine / OR-clock-drift residual misses. | Raw verifier output (3 values)missingSignatureHoldRate=1; residualBoundaryFnCount=14; totalHoldCount=128 |
Pre-operative safety check / SURG-FIND-01-S-PUB-VITALDB | Boundary | Stage S-PUB anchored on 2,400 distinct SNUH VitalDB surgical stays (0 prospective OR trials)Binds every pre-op safety scenario's age, sex, and serum creatinine (plus 8 real -30d to -48h vs -48h creatinine surges) to 2,400 unique SNUH VitalDB surgical stays without raw subject identifiers or synthetic AUROC claims; on-premise hospital EMR/PACS live OR interlock trials remain unexecuted (0 cases). | |
Pre-operative safety check / SURG-FIND-02-CONSENT-SIGNATURE-HOLD | Hold | Missing consent signatures & handwritten corrections trigger bedside HOLDAll 90/90 missing surgeon/witness signature scenarios and smudged handwritten laterality amendments (128 total HOLDs) require verbal time-out verification before incision. | |
Pre-operative safety check / SURG-FIND-03-STALE-SCR-CLOCK-DRIFT | Negative | Residual misses when pre-admission creatinine masks real SNUH acute eGFR dip or OR clock drifts14 non-laterality boundary scenarios passed pre-op rules when -30d..-48h baseline VitalDB creatinine masked a real acute inpatient creatinine rise below eGFR 30 mL/min or anesthesia timestamps drifted by 3 minutes. | |
| Tablet identification and DUR / G1 | Pass | Real ePillID JPEG archive, 5-fold split disjointness & SHA-256 provenanceVerified SHA-256 of ePillID_data.zip (5648 real decoded JPEGs), all_labels.csv (13,532 rows), Fold-3 calibration CSV (745), Fold-4 holdout CSV (745), and 0 image/type leakage. | Raw verifier output (4 values)calTestImgOverlap=0; calTestTypeOverlap=0; decodedRealImages=5648; epillZipSha256=b960b3b1f0ee145ae2be7cfe188de1feaba4286b5d2fb7388004d151ad7311ac |
| Tablet identification and DUR / G2 | Pass | Split-conformal abstention (|C(x)| > 1 -> HOLD) & 6-category MFDS DUR interlockRecomputed Fold-3 conformal threshold q_hat = 0.728379 (alpha = 0.05), verified 0 autonomous clearances when |C(x)| > 1, and 150/150 interceptions in 12 synthetic DUR templates. This is not an independent validation of all 48 catalog rules. | Raw verifier output (15 values)catalogRuleCount=48; conformalAbstentionBypasses=0; durEvaluationScope=SYNTHETIC_SCENARIO_REPETITIONS; durScenarioRepetitions=150; durScenarioTemplateCount=12; fullCatalogClinicalValidationCompleted=false; mfdsDurCategoryCounts: (AGE_CONTRAINDICATION=25, CONTRAINDICATED_COADMIN=25, DOSE_CEILING=25, DURATION_CEILING=25, PREGNANCY_CONTRAINDICATION=25, THERAPEUTIC_DUPLICATION=25); mfdsDurSilentPasses=0; recomputedQHat=0.7284; singletonMismatchBypasses=0 |
| Tablet identification and DUR / G3 | Pass | Independent accepted Top-1 accuracy & >= 95% split-conformal coverage checkAccepted singleton (|C(x)| = 1) Top-1 accuracy = 0.966877 (613/634, Wilson 95% CI [0.949895, 0.978235]) vs 0.90604 unguarded Top-1; Fold-4 coverage = 0.965101. | Raw verifier output (5 values)acceptedSingletonTop1=0.9669; acceptedSingletonWilson95: [0.9499, 0.9782]; conformalEmpiricalCoverage=0.9651; hazardInterceptionRate=1; unguardedTrayTop1=0.906 |
| Tablet identification and DUR / G4 | Pass | White round look-alike abstention rate & unassisted 192-class retrieval boundaryWhite round look-alike tablets trigger HOLD at 0.295918 (58/196) vs 0.096539 (53/549) on colored/oblong pills; 192-class open Top-1 = 0.451007. | Raw verifier output (4 values)nonWhiteRoundHoldRate=0.0965; openGallery192Top1=0.451; openGallery192Top5=0.7477; whiteRoundHoldRate=0.2959 |
Tablet identification and DUR / DISP-FIND-01-WHITE-ROUND-LOOKALIKE-HOLD | Hold | Visually ambiguous white round tablets trigger split-conformal HOLD abstentionUnder real consumer lighting in Fold-4, white round low-chroma tablets yield |C(x)| > 1 in 0.295918 (58/196) of cases vs 0.096539 on colored/oblong pills, preventing unsafe look-alike guessing by routing to pharmacist imprint/barcode check. | |
Tablet identification and DUR / DISP-FIND-02-OPEN-GALLERY-192-CEILING | Negative | Unassisted 192-class consumer-to-NIH Color/Shape retrieval ceiling without OCR/BarcodeAcross all 192 Fold-4 gallery classes without active ATC canister constraints or high-resolution imprint OCR, CIE L*a*b* + contour descriptors reach 0.451007 Top-1 (0.747651 Top-5), leaving 0 singleton physical swap misses out of 300 total hazards. | |
Tablet identification and DUR / DISP-FIND-03-ATC-HARDWARE-HIRA-SYNC | External | Cross-polarized ATC camera rig calibration & live HIRA DUR master table syncHospital pharmacy deployment requires physical cross-polarized LED calibration on multi-pill pouch packagers and daily synchronization with the live HIRA DUR ingredient/contraindication master database. | |
| Ligand affinity and CRO check / G1 | Pass | 8 crystal pockets (4DJW/3OVX + 6 PLB), 195 ligands, 177 LOMAP edges & CRO linkVerified SHA-256 digests across 37 raw provenance files: 8 crystal pockets (4DJW 129, 3OVX 120, 6 OpenFF PLB targets), 195 experimental ligands (73 D3R GC4 + 122 PLB Wang2015), 177 LOMAP ddG edges, and cro_bridge-audit.json PASS. | Raw verifier output (15 values)croAdvancedLeads: GLN-501-A, GLN-501-B, GLN-502-C; croRawMeasurementsRecomputed=true; lomapEdgesVerified=177; pdb3ovxPocketHeavyAtoms=120; pdb4djwPocketHeavyAtoms=129; plbPocketHeavyAtoms: (cdk2=139, mcl1=134, p38=162, ptp1b=183, thrombin=161, tyk2=140); plbTargetsVerified=6; smilesOverlap=0; totalD3rCompounds=195; totalTargets=8 |
| Ligand affinity and CRO check / G2 | Pass | 195-ligand ΔG / 177-edge ΔΔG conservation & synthetic Zwanzig/BAR cycle-closure gateVerified experimental ΔG across all 195 complexes and ΔΔG across all 177 LOMAP edges; replayed work-derived midpoint estimates and graph projection, with synthetic cycle residual max |sum ddG| = 1e-05 kcal/mol (< 0.05) with 1 ring-opening edge (hysteresis > 0.8 kcal/mol) routed to HOLD. | Raw verifier output (10 values)cycleResidualsKcal: (Hex_Wing_60_10_75_63=0, Primary_4Cycle_60_61_62_63=1.00e-05, Spoke_Triangle_60_61_62=0, Spoke_Triangle_61_62_63=0); highHysteresisHoldEdges=1; maxCycleResidualKcal=1.00e-05; syntheticInterlockBenchmark=true; syntheticWorkMatchesReference=true; syntheticWorkReferenceSamples=5760; workDerivedProjectionCheckedEdges=9 |
| Ligand affinity and CRO check / G3 | Pass | Out-of-fold 195-complex Spearman rho, blind 8-target LOTO & 177-edge LOMAP LEEORecomputed 195-complex LOO rho = 0.806822 (95% CI [0.724612, 0.871056]), RMSE = 0.855653 kcal/mol, 5-fold rho = 0.794025 (vs -MW null 0.26533); blind 8-target LOTO mean within-target rho = 0.484466; 177-edge LOMAP LEEO within-target ddG rho = 0.537108 (RMSE = 1.130442 kcal/mol). | Raw verifier output (64 values)boltz2ZeroShotLomapMeanWithinTargetRho=0.5858; boltz2ZeroShotMeanWithinTargetRho=0.6672; expectedPredictionReferenceCount=939; expectedV3PredictionReferenceCount=1329; fiveFoldRmseKcalMol=0.8804; fiveFoldSpearmanRho=0.794; independentPredictionReferenceMatched=true; independentPredictionReferenceSha256=61dd5ac3682ea9f7766a327b1c1c2e8bc4753ddaa7603c82bca453f4bf1b3c70; independentReplayExecutedInThisAudit=true; independentReplayVerification: (comparisonSummary={'LEEO_pooled': {'mismatchCount': 0, 'n': 177}, 'LEEO_within': {'mismatchCount': 0, 'n': 177}, 'LOO': {'mismatchCount': 0, 'n': 195}, 'LOTO': {'mismatchCount': 0, 'n': 195}, 'fiveFold': {'mismatchCount': 0, 'n': 195}, 'v3_LEEO_pooled': {'mismatchCount': 0, 'n': 177}, 'v3_LEEO_within': {'mismatchCount': 0, 'n': 177}, 'v3_LOO': {'mismatchCount': 0, 'n': 195}, 'v3_LOTO_inductive': {'mismatchCount': 0, 'n': 195}, 'v3_LOTO_transductive': {'mismatchCount': 0, 'n': 195}, 'v3_fiveFold': {'mismatchCount': 0, 'n': 195}, 'v3_zeroShotVina': {'mismatchCount': 0, 'n': 195}}, executed=true, modelDigestsMatched=true, molecularWeightsMatched=true, partitionIdsMatched=true, passed=true, poseIdentityMatched=true, predictionsMatched=true, preprocessingDigestsMatched=true, replayCodeProductImportFree=true, replayCodeSha256=e8f449773343b7fdb6cb8a8e23130ccc7c81ebd65558262ef3b3e925b5b9b449, returnCode=0, syntheticWorkMatched=true); independentV3PredictionReferenceMatched=true; kendallTau=0.6341; lomapPooledDdgRmseKcalMol=1.1165; lomapPooledDdgSpearmanRho=0.4922; lomapWithinTargetDdgMaeKcalMol=0.8275; lomapWithinTargetDdgRmseKcalMol=1.1304; lomapWithinTargetDdgSpearmanRho=0.5371; lotoMeanWithinTargetSpearmanRho=0.4845; lotoPerTargetSpearmanRho: (BACE1=0.4988, Cathepsin-S=0.423, cdk2=0.1273, mcl1=0.75, p38=0.4951, ptp1b=0.7025, thrombin=0.5604, tyk2=0.3187); lotoPooledSpearmanRho=0.1737; lotoRmseKcalMol=1.4525; maeKcalMol=0.6181; molecularWeightReferenceCount=195; molecularWeightsMatchReference=true; mwNullSpearmanRho=0.2653; pearsonR=0.8005; pinnedReferenceVerification: (establishesLiveTrainingReplay=false, matched=true, rawInputsVerifiedCount=37, referenceSha256=61dd5ac3682ea9f7766a327b1c1c2e8bc4753ddaa7603c82bca453f4bf1b3c70, replayCodeProductImportFree=true, replayCodeSha256=e8f449773343b7fdb6cb8a8e23130ccc7c81ebd65558262ef3b3e925b5b9b449, v2PredictionCount=939, v3FoldProvenanceDigestsMatched=true, v3PredictionCount=1329); rmseKcalMol=0.8557; spearmanCi95: [0.7246, 0.8711]; spearmanRho=0.8068; v3FoldProvenanceFormatVerified=true; v3LotoInductiveRmseKcalMol=1.4525; v3LotoTransductiveBatchRmseKcalMol=1.3742; v3PoseProvenanceVerified=true; v3PoseSourceCounts: (absent_smiles_only=73, generated_o3a_aligned=1, provided_sdf_pose=121); v3ZeroShotVinaProvidedSdfMeanRho=0.4531 |
| Ligand affinity and CRO check / G4 | Pass | Blind LOTO gap, synthetic interlock scope, hysteresis HOLD & wet CRO boundaryDiscloses blind 8-target LOTO extrapolation drop (mean within-target rho = 0.484466 vs pooled LOO rho = 0.806822), labels Zwanzig/BAR cycle closure as a synthetic interlock testbed (distinct from 177 empirical LOMAP edges), preserves macrocycle HOLD, held GLN-502-D, and 0 executed external wet-lab CRO syntheses. | Raw verifier output (6 values)baceSpearmanRho=0.7158; catsSpearmanRho=0.7368; executedExternalWetCroCount=0; heldCroCandidates: GLN-502-D; lotoMeanWithinTargetSpearmanRho=0.4845; syntheticInterlockBenchmark=true |
Ligand affinity and CRO check / DRUG-FIND-01-LOTO-VS-LEEO-SEPARATION | Boundary | Within-target LOO/LOMAP signal outperforms blind cross-target LOTO extrapolationExcluding each held-out target's ligands from fitting gives LOTO mean within-target rho = 0.484466 (pooled 0.173742); target structural features are retained, whereas ligand-series LEEO across 177 OpenFF LOMAP perturbations achieves within-target ddG rho = 0.537108. | |
Ligand affinity and CRO check / DRUG-FIND-02-SYNTHETIC-BAR-INTERLOCK-HOLD | Hold | Synthetic BAR interlock testbed closes (< 0.05 kcal/mol) & routes hysteresis > 0.8 to HOLDThe 12-lambda Zwanzig/BAR perturbation cycle-closure graph is explicitly labeled a synthetic interlock benchmark; the non-core ring-breaking edge exceeds 0.8 kcal/mol hysteresis and is routed to HOLD. | |
Ligand affinity and CRO check / DRUG-FIND-03-GLN502D-AND-WET-CRO-UNEXECUTED | Hold | Candidate GLN-502-D held on LM 4PL / hERG & external wet CRO execution remains 0CRO-Bridge raw plate 4PL refit holds pyrazole-nitrile GLN-502-D (IC50 > 100 nM, hERG margin < 100x), and actual external CRO wet synthesis / animal PK / GLP toxicity remains 0 executed. | |
| CRO / G1 | Pass | G1_zero_custody_and_noveltyIndependent 4PL IC50 & PK audit gate | Raw verifier output (1 values)sponsorPhysicalCustody=false |
| CRO / G2 | Pass | G2_coa_and_plate_qcIndependent 4PL IC50 & PK audit gate | Raw verifier output (3 values)minPurityObservedPct=96.4; minZPrimeObserved=0.9052; violations: [] |
| CRO / G3 | Pass | G3_raw_4pl_and_pk_recomputationIndependent 4PL IC50 & PK audit gate | Raw verifier output (3 values)discrepancies: []; max4PlRmsePct=1.5587; solverFreeVerified=true |
| CRO / G4 | Pass | G4_honest_advancement_and_holdsIndependent 4PL IC50 & PK audit gate | Raw verifier output (2 values)advancedLeads: GLN-501-A, GLN-501-B, GLN-502-C; heldCompounds: GLN-502-D |
| CORE / G1 | Pass | 12 track audit statuses and Audit/Run SHA-256 receipt bindingVerified all 12 public-cohort audit records and run bindings. Exact PASS or justified performance-HOLD statuses and their reasons are preserved. Core PASS certifies schema/receipt linkage, not clinical performance. | Raw verifier output (17 values)trackAuditStatusCounts: (BLOCK=0, HOLD=0, PASS=12); trackAuditStatuses: (aorta11_31=PASS, dementia16_3=PASS, dispense18_v2=PASS, drug5_1=PASS, ecg11_36=PASS, fetal13_2=PASS, icu11_61=PASS, omics11_63=PASS, rare19_v2=PASS, surg18_3=PASS, twin11_32=PASS, xray11_12=PASS); tracksAtSPub=12; verifiedReceipts=12 |
| CORE / G2 | Pass | KR CDI v2 (14 classes, notice 2025-244), FHIR R4 KR core & CODA zero-PHI lockVerified 36/36 KR CDI + HL7 FHIR R4 KR Core profiles (including 4 Notice 2025-244 items) and 12/12 5-section KDCA CODA DMP packages with zero PHI / raw clinical files. | Raw verifier output (3 values)codaPackagesFulfilled=12; fhirUnitsFulfilled=36; rawMedicalFilesLeakedInSite=0 |
| CORE / G3 | Pass | 60-unit internal regulatory schema & track 95% CI tie-outIndependently recomputed 60/60 (1.0, 95% CI [0.939828, 1.0]) and verified exact primaryMetric & CI95 alignment across all 12 track audit receipts. | Raw verifier output (4 values)fulfilledUnits=60; statutoryConformanceProportion=1; totalUnits=60; wilson95: [0.9398, 1] |
| CORE / G4 | Pass | MFDS SaMD (11 tracks) vs non-SaMD drug discovery and zero formal approvalsVerified 11 SaMD tracks (IEC 62304 Class B/C, 19-item clinician notice) vs 1 non-SaMD drug-discovery exclusion, preserved HOLD/BLOCK escalations, 0 MFDS approvals, 0 external CRO reports, 0 clinical IRB studies, and an empty human auditor signature. | Raw verifier output (6 values)clinicalIrbCount=0; externalCroCount=0; humanAuditorSignature=null; mfdsApprovalCount=0; nonSamdTrack=drug5_1; samdTrackCount=11 |
CORE / CORE-FIND-01-NOTICE-2025-244 | Pass | All 12 S-PUB tracks mapped across 14 KR CDI classes & 4 new notice 2025-244 itemsCompiles 36 HL7 FHIR R4 KR Core profiles carrying advance directive, medication order timestamp, alcohol status, and smoking status alongside KCD-8, SNOMED CT, LOINC, HIRA EDI, and WHO ATC URIs. | |
CORE / CORE-FIND-03-PERFORMANCE-HOLD-PRESERVED | Boundary | Core linkage does not promote performance HOLD to PASSSource audit statuses are PASS=12, HOLD=0, BLOCK=0. Only an explained G3 performance HOLD with verified metrics and other integrity gates PASS is publishable. Publication also requires fresh independent track-audit replay in the integrated release gate. | |
CORE / CORE-FIND-02-ZERO-APPROVAL-HONESTY | External | Zero formal MFDS approvals or clinical IRB submissions executed in stage 0GALENOS Core prepares machine-auditable KR CDI v2, KDCA CODA DMP, and MFDS technical dossier scaffolds; formal MFDS SaMD clearance (0), clinical IRB trials (0), and external CRO wet-lab assays (0) remain external Stage 1+ steps. |