Explore the medical research group

6 sites · 85 research, tool & source destinations

GALENOSResearch computation & execution records

IATHEONCancer mechanisms & treatment hypotheses

NOEMATHEONMental health mechanisms, measures & recovery

HEBEAging, regeneration & functional recovery

APOSTOLUSResearch sources & implementation contracts

TESTIEDIntegrity evidence for medical-event records

Calculations & specialist research

GALENOSResearch computation & execution records

Calculations & checks

IATHEONCancer mechanisms & treatment hypotheses

NOEMATHEONMental health mechanisms, measures & recovery

HEBEAging, regeneration & functional recovery

APOSTOLUSResearch sources & implementation contracts

TESTIEDIntegrity evidence for medical-event records

Audit receipt

Ventilation and gas-exchange calculator

Calculates model quantities from ventilation settings, compliance and hemoglobin. It does not predict sepsis, ARDS onset or patient survival.

Choose another tool

Interactive Medical Visualizer

Open full Atlas DB & 3D Lab

MIMIC-IV ARDS V/Q Shunt & Driving Pressure

Track ICU P/F ratio and driving pressure against the 15 cmH2O ARDSNet protective ceiling.

Frozen-cohort evaluation record S-PUB

These are frozen-cohort evaluation records. The evaluated-model form uses those preprocessing steps and weights. These metrics do not establish the scope of separate mathematical calculators or the full research scope.

MIMIC-IV First-24h subject-locked ICU deterioration AUROC 0.8079 AUROC Target: 100% real <=24h charttime & storetime MIMIC-IV trajectories + West V/Q shunt & Delta P solver; zero subject crossing
95% CI & denominator [0.6723, 0.9197] 50 subjects / 66 stays
Baseline comparison 0.6749 AUROC Admission Single-Vital Shock Index (HR/SBP)
External CRO & IRB status 0 / 0 CRO: 0, Clinical IRB: 0

1. Supplied-input calculation and verification

Run after entering values to create a new calculation and hash. Editing clears the previous result.

Calculates model quantities from ventilation settings, compliance and hemoglobin. It does not predict sepsis, ARDS onset or patient survival.

Input parameters

POST /api/run/ventilator
Fill a calculation example

Direct input: missing measurements are not filled automatically.

Inspect request inputs
{}
Ready
POST /api/run/ventilator

Enter values and run. Examples are labeled. A numerical PASS does not establish clinical validity or full capability.

input SHA-256: pending output SHA-256: pending humanAuditorSignature: null

2. Locked-cohort secondary metrics

Metric Observed
Holdout ICU deterioration probability Brier score0.1459 Brier (n=66)
Holdout 10-bin expected calibration error (ECE)0.0962 ECE
West 3-compartment shunt O2 flux conservation max residual3.92e-06 mL O2/dL
Ventilated stays triggering delta P > 15 cmH2O barotrauma HOLD11 stays / 140
Ventilated stays triggering missing-ABG SpO2-plateau HOLD1 stays / 140
First-24h ICU chart events retained (Post-24h excluded)24194 events (excl 63924)

Extracts timestamp-verified (0 <= t <= 24h) vital, ventilator (FiO2, PEEP, Pplat, VT), and arterial blood gas series from PhysioNet MIMIC-IV Demo v2.2, couples them with exact alveolar gas, Severinghaus-Hill O2 content, and driving-pressure mechanics, and fits regularized risk stratification strictly on subject-disjoint training stays.

Audited offline reference cases

PASS means the input and computation gates passed for that case. It is not a clinical verdict. HOLD means the automated output was withheld.

Pass Compute gate only, not a clinical verdict icu-case-01-real-ards-responder

Case 01 · Hypoxemic Respiratory Failure Recruitment Responder (Real MIMIC-IV Stay)

Real first-24h MIMIC-IV ventilator and ABG trajectory showing PaO2/FiO2 recovery and falling West shunt under lung-protective driving pressure.

24h PaO2/FiO2 (mmHg)
200
24h deterioration risk
0.808
24h intrapulmonary shunt (%)
19.3
Arterial blood gas draws (24h)
5
Initial PaO2/FiO2 (mmHg)
85.7
Max driving pressure (cmH2O)
13.3
Safety gate reason
PASS (Lung-protective Delta P <= 15 cmH2O)

3. Solver-free independent audit gates (G1-G4)

solverFree = True
Gate Status Specification & verification detail Observed summary
G1PassMIMIC-IV 7-table SHA-256, subject split & <=24h real trajectory lockVerified all 7 MIMIC-IV Demo v2.2 .csv.gz tables on disk, zero subject crossing across 140 stays, zero hand-typed arrays, and strict 0 <= offset <= 24.0h timestamps.
Raw verifier output (4 values)train_subjects=50, test_subjects=50 (stays=66); max_offset=23.98h (<=24.0h); excluded_post24_chart=63924
G2Pass3-compartment West lung O2 flux conservation & delta P safety lawVerified CaO2 = (1 - Qs/Qt)*Cc'O2 + (Qs/Qt)*CvO2 to <1e-5 mL/dL via Severinghaus-Hill dissociation and confirmed Delta P > 15 cmH2O barotrauma detection on real stay states.
Raw verifier output (3 values)max_O2_flux_residual=3.92e-06 mL/dL; barotrauma_states_verified=1; vq_states=4
G3PassSolver-free subject-locked ICU deterioration AUROC & calibration auditIndependently recomputed holdout ICU deterioration AUROC, 95% bootstrap CI, Brier score, and ECE without solver imports, confirming gain over admission shock-index.
Raw verifier output (3 values)holdout_AUROC=0.8079 [0.6723, 0.9197] vs shock_index_base=0.6749; Brier=0.1459, ECE=0.0962
G4PassBarotrauma (delta P > 15 cmH2O) & missing-ABG HOLD gates + KR ICU gateVerified automatic HOLD gates on both real Delta P > 15 cmH2O barotrauma stays and ventilated stays lacking 24h arterial PaO2, plus KR CDI / HL7 FHIR requirements.
Raw verifier output (3 values)cohort_barotrauma_stays=11, missing_ABG_stays=1; workbench_HOLD_cases=2

Preserved limitations, boundaries, and HOLDs

  • Boundary MIMIC-IV Demo sample size (100 subjects, 140 stays) widens holdout confidence interval
    Across 66 subject-disjoint holdout ICU stays, coupling West V/Q shunt and driving pressure with first-24h organ-dysfunction labs reaches AUROC 0.8079 (95% CI 0.6723-0.9197) versus shock-index 0.6749; tighter CIs require multi-thousand-stay hospital cohorts.
  • Hold Dual bedside safety interlocks: Delta P > 15 cmH2O barotrauma & missing-ABG SpO2 plateau
    In real MIMIC-IV ventilator series, 11 stays exceed 15 cmH2O driving pressure and 1 ventilated stays lack 24h arterial PaO2 at SpO2 >= 97%; both states trigger mandatory HOLD to block unsafe PEEP escalation or ill-posed shunt inversion.
  • External Domestic tertiary ICU external recalibration & KR CDI / HL7 FHIR streaming gate
    Because antibiotic timing, ventilator weaning protocols, and ARDS etiology differ between US Beth Israel Deaconess and Korean tertiary ICUs, domestic multi-center IRB recalibration and HL7 FHIR R4 bedside integration remain external gates.

Unexecuted external statutory steps & dossier checklist

  • KR CDI / HL7 FHIR ICU vital-sign streaming conformance
  • Multi-center Korean tertiary ICU retrospective calibration (unexecuted)
  • Alveolar-arterial O2 gradient & shunt fraction conservation check
  • Driving pressure (> 15 cmH2O) barotrauma safety alert verification
  • Strict first-24h observation window timestamp leakage check
  • Real MIMIC-IV stay trajectory extraction provenance

4. Frozen input SHA-256 provenance and internal replay CLI

Public provenance JSON
Input archive / manifestRecordsSHA-256
PhysioNet MIMIC-IV Demo v2.2 (icustays.csv.gz)140e05e81aa52a3022e522b6832a898101a69b84e64c17bb344d819e458d5bc21b3
PhysioNet MIMIC-IV Demo v2.2 (admissions.csv.gz)275910b9f160ffdf1e08ea673585393f347c773ccc87d66875c627584a903ae8493
PhysioNet MIMIC-IV Demo v2.2 (patients.csv.gz)10059dcc6cd8450ddf03ad32cc7d76e41caa4c9633541715987f590c74835cf6fae
PhysioNet MIMIC-IV Demo v2.2 (chartevents.csv.gz)668,86290f096ad3db847ed1aaec073f8d86053c51fea7b616d3b046410e030f083d560
PhysioNet MIMIC-IV Demo v2.2 (labevents.csv.gz)107,727d51a4cf1ea63245abe7d544b0d50a928e9ee2ec5eb9a5ce85500aed0bd6c6dfc
PhysioNet MIMIC-IV Demo v2.2 (d_items.csv.gz)4,0141690467a822345226a041c1149237c418aa60098c6b699fb4cef64d73588a01f
PhysioNet MIMIC-IV Demo v2.2 (d_labitems.csv.gz)1,62272ea5f020469fd24543bd98ab3bd0a4f645a5a4b7802d9d52af20d736f9d76db
Internal maintainer CLI (local repo .venv only): ./scripts/check