Direct vendor-to-CRO assay dispatch and raw plate recomputation
External wet-lab CRO orders executed to date: 0. When raw plate reader fluorescence CSVs and plasma PK tables arrive from an ISO-17025 / GLP vendor, this verifier independently recomputes Levenberg-Marquardt 4PL IC50, Z'-factor, and linear-up/log-down trapezoidal AUC.
1. Live 4PL IC50 and non-compartmental PK raw plate verifier
Fits dose-response data with controls and computes PK quantities from supplied time/concentration measurements. Does not authenticate measurements or establish that an experiment took place.
Input parameters
POST /api/run/cro
Ready
POST /api/run/cro
Enter values and run. Examples are labeled. A numerical PASS does not establish clinical validity or full capability.
2. Raw multi-modal artifact verification (AWS ap-northeast-2 Lambda, S3, KMS)
Streams raw VCF, CSV, 3D NIfTI, tablet JPEG/PNG, ECG/CTG CSV, and SDF/SMILES payloads to ap-northeast-2 AWS Lambda, storing inputs in S3 and immutable KMS-signed receipts in AWS RDS PostgreSQL 16. DUR screening uses a curated 28-rule active-ingredient subset (curated_mfds_hira_subset), distinct from the 5-drug JSON form demo, 9-feature clinical surrogate, or any national drug master DB.
VCF + HPO genomics upload
/api/upload/vcf
Parses raw VCF (.vcf/.vcf.gz), ranks across 4,900 HPO genes (Resnik/Lin IC), scores ClinGen-excluded ACMG-28 criteria, and commits an S3+RDS+KMS receipt.
Ready: select a real clinical or chemical artifact and submit.
Raw plate assay CSV verifier
/api/upload/plate-csv
Fits a strict Levenberg-Marquardt 4PL curve directly from raw CSV rows. Rejects corrupted or NaN files with HTTP 400 BLOCK without silent fallback.
Ready: select a real clinical or chemical artifact and submit.
3D NIfTI volume geometry & slice
/api/upload/nifti
Reads 3D NIfTI (.nii/.nii.gz) voxel zooms, affine determinant, intensity quantiles, Tenengrad sharpness, and renders a decoded mid-slice preview.
Ready: select a real clinical or chemical artifact and submit.
Pill photo ID + curated DUR 28-rule
/api/upload/pill-image
Extracts 55D CIE L*a*b* and contour features against all 4,902 NIH ePillID prototypes (Fold-3 q_hat=0.956757). DUR screens a curated 28-rule active-ingredient subset (not the full national master).
Ready: select a real clinical or chemical artifact and submit.
Raw ECG / CTG waveform CSV
/api/upload/waveform
Computes Pan-Tompkins R-peaks/SDNN/SNR for ECG CSV. For CTG traces it computes, over 1-minute artifact/decel-free windows, a valid-sample median baseline and a within-minute 3.75-second (1/16-min) epoch STV proxy (adapted from the antepartum Dawes-Redman STV epoch formula; not intrapartum FIGO clinical criteria).
Ready: select a real clinical or chemical artifact and submit.
RDKit 3D conformer, MMFF94 & Bennett BAR
/api/upload/chemistry
Builds RDKit ETKDGv3 + MMFF94 3D conformers from SMILES or SDF/MOL files and computes exact nonlinear Bennett BAR when work arrays are supplied.
Ready: select a real clinical or chemical artifact and submit.
RISCON Labs operates computational design and audit software only, holding zero wet lab, animal room, or chemical reagent inventory.
When wet validation is commissioned, a synthesis vendor ships coded aliquots directly to an ISO/IEC 17025 or GLP contract research organization (currently 0 wet orders executed).
Only raw instrument files (plate reader RFU CSV/JSON, LC-MS/MS purity tables, plasma PK concentrations) enter the audit pipeline for independent 4PL and trapezoidal AUC recomputation.
Before any human Phase I IND filing, pivotal safety pharmacology and toxicology must be completed at an MFDS-designated GLP non-clinical institution.
Permitted external clinical advisory scope
CLIN-1: MFDS SaMD intended-use definition and risk analysis Under a written clinical advisory contract, an external board-certified specialist can review intended use, ISO 14971 clinical hazard severity, and adjudication rules without full-time employment.
CLIN-2: IEC 62366-1 formative usability walkthroughs Practicing obstetricians and hospital clinicians can participate in formative interface hazard reviews (alarm fatigue, hold-state clarity, units).
CLIN-3: Institutional joint research or retrospective IRB validation site Institution-level collaboration with an accredited hospital IRB is required before evaluating any non-public Korean patient records.
Conflict-of-interest and regulatory boundaries
CriticalCOI-1: Internal rule: prior disclosure for related-party advisory fees RISCON Labs discloses any conflict of interest in writing before paying an advisory or service fee to a related party. Unpaid advisory agreements, or agreements between independent institutions, involve no payment to the related party.
CriticalCOI-2: MFDS pivotal trial principal investigator independence Confirmatory clinical trials for MFDS approval must run at an MFDS-designated clinical trial institution under an independent Principal Investigator with full IRB COI disclosure.
HighCOI-3: Manufacturer quality manager must be an in-house employee Under Medical Devices Act Art. 6-2, a licensed manufacturer's Quality Manager cannot be an external advisor; an in-house manager is designated at manufacturing license application.