Explore the medical research group

6 sites · 85 research, tool & source destinations

GALENOSResearch computation & execution records

IATHEONCancer mechanisms & treatment hypotheses

NOEMATHEONMental health mechanisms, measures & recovery

HEBEAging, regeneration & functional recovery

APOSTOLUSResearch sources & implementation contracts

TESTIEDIntegrity evidence for medical-event records

Calculations & specialist research

GALENOSResearch computation & execution records

Calculations & checks

IATHEONCancer mechanisms & treatment hypotheses

NOEMATHEONMental health mechanisms, measures & recovery

HEBEAging, regeneration & functional recovery

APOSTOLUSResearch sources & implementation contracts

TESTIEDIntegrity evidence for medical-event records

Audit receipt

Direct vendor-to-CRO assay dispatch and raw plate recomputation

External wet-lab CRO orders executed to date: 0. When raw plate reader fluorescence CSVs and plasma PK tables arrive from an ISO-17025 / GLP vendor, this verifier independently recomputes Levenberg-Marquardt 4PL IC50, Z'-factor, and linear-up/log-down trapezoidal AUC.

1. Live 4PL IC50 and non-compartmental PK raw plate verifier

Fits dose-response data with controls and computes PK quantities from supplied time/concentration measurements. Does not authenticate measurements or establish that an experiment took place.

Input parameters

POST /api/run/cro
Fill a calculation example

Direct input: missing measurements are not filled automatically.

Inspect request inputs
{}
Ready
POST /api/run/cro

Enter values and run. Examples are labeled. A numerical PASS does not establish clinical validity or full capability.

input SHA-256: pending output SHA-256: pending humanAuditorSignature: null

2. Raw multi-modal artifact verification (AWS ap-northeast-2 Lambda, S3, KMS)

Streams raw VCF, CSV, 3D NIfTI, tablet JPEG/PNG, ECG/CTG CSV, and SDF/SMILES payloads to ap-northeast-2 AWS Lambda, storing inputs in S3 and immutable KMS-signed receipts in AWS RDS PostgreSQL 16. DUR screening uses a curated 28-rule active-ingredient subset (curated_mfds_hira_subset), distinct from the 5-drug JSON form demo, 9-feature clinical surrogate, or any national drug master DB.

VCF + HPO genomics upload

/api/upload/vcf

Parses raw VCF (.vcf/.vcf.gz), ranks across 4,900 HPO genes (Resnik/Lin IC), scores ClinGen-excluded ACMG-28 criteria, and commits an S3+RDS+KMS receipt.

Enter the observed phenotypes for this case. Nothing is prefilled; the placeholder is only a format example.

Ready: select a real clinical or chemical artifact and submit.

Raw plate assay CSV verifier

/api/upload/plate-csv

Fits a strict Levenberg-Marquardt 4PL curve directly from raw CSV rows. Rejects corrupted or NaN files with HTTP 400 BLOCK without silent fallback.

Ready: select a real clinical or chemical artifact and submit.

3D NIfTI volume geometry & slice

/api/upload/nifti

Reads 3D NIfTI (.nii/.nii.gz) voxel zooms, affine determinant, intensity quantiles, Tenengrad sharpness, and renders a decoded mid-slice preview.

Ready: select a real clinical or chemical artifact and submit.

Pill photo ID + curated DUR 28-rule

/api/upload/pill-image

Extracts 55D CIE L*a*b* and contour features against all 4,902 NIH ePillID prototypes (Fold-3 q_hat=0.956757). DUR screens a curated 28-rule active-ingredient subset (not the full national master).

Clinical fields start blank. Blank means unknown and holds the DUR check; no example patient is submitted with your file.

Ready: select a real clinical or chemical artifact and submit.

Raw ECG / CTG waveform CSV

/api/upload/waveform

Computes Pan-Tompkins R-peaks/SDNN/SNR for ECG CSV. For CTG traces it computes, over 1-minute artifact/decel-free windows, a valid-sample median baseline and a within-minute 3.75-second (1/16-min) epoch STV proxy (adapted from the antepartum Dawes-Redman STV epoch formula; not intrapartum FIGO clinical criteria).

Ready: select a real clinical or chemical artifact and submit.

RDKit 3D conformer, MMFF94 & Bennett BAR

/api/upload/chemistry

Builds RDKit ETKDGv3 + MMFF94 3D conformers from SMILES or SDF/MOL files and computes exact nonlinear Bennett BAR when work arrays are supplied.

Ready: select a real clinical or chemical artifact and submit.

3. Offline synthetic fixture verification table (0 wet orders executed)

Compound & target Recomputed IC50 Reported IC50 (diff) Z'-factor Recomputed AUC hERG margin Decision
GLN-501-ABACE1 / Spiro-oxazine-aminoimine18.01 nM18.01 nM (0.01%)0.92586545.54 ng·h/mL1576.9xAdvance hit-to-lead
GLN-501-BBACE1 / Cyclopropyl-alkynyl-iminohydantoin41.76 nM41.75 nM (0.01%)0.93315041.23 ng·h/mL459.8xAdvance hit-to-lead
GLN-502-CCathepsin-S / Norbornyl-sulfonyl-nitrile9.8 nM9.81 nM (0.07%)0.91298931.06 ng·h/mL4182.0xAdvance hit-to-lead
GLN-502-DCathepsin-S / Pyrazole-tetrahydropyran-nitrile334.09 nM335.13 nM (0.31%)0.90521848.42 ng·h/mL25.1xHold: potency / hERG

Direct vendor-to-CRO operating rules

  • RISCON Labs operates computational design and audit software only, holding zero wet lab, animal room, or chemical reagent inventory.
  • When wet validation is commissioned, a synthesis vendor ships coded aliquots directly to an ISO/IEC 17025 or GLP contract research organization (currently 0 wet orders executed).
  • Only raw instrument files (plate reader RFU CSV/JSON, LC-MS/MS purity tables, plasma PK concentrations) enter the audit pipeline for independent 4PL and trapezoidal AUC recomputation.
  • Before any human Phase I IND filing, pivotal safety pharmacology and toxicology must be completed at an MFDS-designated GLP non-clinical institution.

Permitted external clinical advisory scope

  • CLIN-1: MFDS SaMD intended-use definition and risk analysis
    Under a written clinical advisory contract, an external board-certified specialist can review intended use, ISO 14971 clinical hazard severity, and adjudication rules without full-time employment.
  • CLIN-2: IEC 62366-1 formative usability walkthroughs
    Practicing obstetricians and hospital clinicians can participate in formative interface hazard reviews (alarm fatigue, hold-state clarity, units).
  • CLIN-3: Institutional joint research or retrospective IRB validation site
    Institution-level collaboration with an accredited hospital IRB is required before evaluating any non-public Korean patient records.

Conflict-of-interest and regulatory boundaries

  • Critical COI-1: Internal rule: prior disclosure for related-party advisory fees
    RISCON Labs discloses any conflict of interest in writing before paying an advisory or service fee to a related party. Unpaid advisory agreements, or agreements between independent institutions, involve no payment to the related party.
  • Critical COI-2: MFDS pivotal trial principal investigator independence
    Confirmatory clinical trials for MFDS approval must run at an MFDS-designated clinical trial institution under an independent Principal Investigator with full IRB COI disclosure.
  • High COI-3: Manufacturer quality manager must be an in-house employee
    Under Medical Devices Act Art. 6-2, a licensed manufacturer's Quality Manager cannot be an external advisor; an in-house manager is designated at manufacturing license application.