ECG QRS feature analysis

Computes QRS, interval and morphology rules from a supplied ECG and sample rate. It is not the trained arrhythmia classifier or a comprehensive diagnosis.

Choose another tool

Interactive Medical Visualizer

Open full Atlas DB & 3D Lab

MIT-BIH DS2 ECG & BeatResCNN1D

Inspect QRS R-peaks and BeatResCNN1D ventricular ectopy fusion across held-out DS2 patients.

Frozen-cohort evaluation record S-PUB

These are frozen-cohort evaluation records. The evaluated-model form uses those preprocessing steps and weights. These metrics do not establish the scope of separate mathematical calculators or the full research scope.

MIT-BIH blind DS2 patient-disjoint ventricular arrhythmia Holter AUROC 0.9781 AUROC Target: 48/48 raw Format-212 waveforms; blind Pan-Tompkins QRS Sens/PPV >= 99%; DS1->DS2 patient-disjoint
95% CI & denominator [0.9448, 0.9959] 22 subjects / 330 stays
Baseline comparison 0.8625 AUROC Fixed Premature RR (<600 ms) Burden Baseline
External CRO & IRB status 0 / 0 CRO: 0, Clinical IRB: 0

1. Supplied-input calculation and verification

Run after entering values to create a new calculation and hash. Editing clears the previous result.

Computes QRS, interval and morphology rules from a supplied ECG and sample rate. It is not the trained arrhythmia classifier or a comprehensive diagnosis.

Input parameters

POST /api/run/ecg
Fill a calculation example

Direct input: missing measurements are not filled automatically.

Inspect request inputs
{}
Ready
POST /api/run/ecg

Enter values and run. Examples are labeled. A numerical PASS does not establish clinical validity or full capability.

input SHA-256: pending output SHA-256: pending humanAuditorSignature: null

2. Locked-cohort secondary metrics

Metric Observed
Blind 48-record Pan-Tompkins QRS sensitivity (+-150 ms vs .atr)99.33 % (109224/109966)
Blind 48-record Pan-Tompkins QRS positive predictive value (+-150 ms)99.61 % (109224/109656)
Blind DS2 49,689-beat ventricular ectopy sensitivity96.47 % (3065/3177)
Blind DS2 49,689-beat ventricular ectopy specificity98.78 % (45945/46512)
Blind DS2 beat-level VEB AUROC (HGB + DS1 1D-CNN fusion)0.9984 AUROC (n=49689 beats, 22 patients)
Blind DS2 ventricular ectopy beat positive predictive value84.39 %
DS2 Holter epoch probability calibration Brier score0.046 Brier (ECE=0.054)
PTB-XL locked Fold-10 12-lead 5-superclass macro AUROC (1,904 unseen patients)0.9332 AUROC (n=2198, 1904 patients, 71-SCP=0.9118)

Unpacks all 48 dual-channel Format-212 360 Hz Holter waveforms, runs blind 5-15 Hz Pan-Tompkins R-peak detection without reading .atr timestamps, extracts RR and dual-lead QRS/ST-T morphology at detected peaks on DS1 (22 patients) -> blind DS2 (22 patients), and couples a 3D cardiac dipole SNR < 6 dB HOLD gate.

Audited offline reference cases

PASS means the input and computation gates passed for that case. It is not a clinical verdict. HOLD means the automated output was withheld.

Pass Compute gate only, not a clinical verdict ecg-case-01-ds2-normal-sinus

Case 01 · Normal Sinus Rhythm (Blind Pan-Tompkins DS2 Trace)

Regular blind-detected R-peaks with narrow QRS template concordance and zero ventricular ectopy.

Detected QRS beats
8
Max VEB probability
0.001
Mean RR interval (ms)
807.3
Patch SNR (dB)
12.5
Safety gate status
PASS
Ventricular ectopy burden (%)
0

3. Solver-free independent audit gates (G1-G4)

solverFree = True
Gate Status Specification & verification detail Observed summary
G1Pass48/48 Format-212 binary waveforms SHA-256 & AAMI DS1/DS2 patient lockVerified all 144 MIT-BIH files (48 .hea + 48 .atr + 48 Format-212 .dat) on disk with zero initial ADC header mismatches and strict 22-vs-22 patient-disjoint DS1/DS2 partitioning.
Raw verifier output (3 values)144/144 files verified; 48/48 .dat ADC init mismatches=0; DS1=22 patients, DS2=22 patients
G2Pass3D cardiac dipole limit-cycle stability & SNR < 6 dB abstention lawConfirmed RK4 unit-circle radial drift (<1e-3), physiological R-peak voltage, and independent signal-to-noise recomputation enforcing automatic HOLD at 3.8 dB.
Raw verifier output (3 values)clean_SNR=18.60 dB (PASS), motion_SNR=3.80 dB (HOLD), max_radial_drift=0.00e+00
G3PassBlind 48-record Pan-Tompkins QRS & DS2 ventricular ectopy auditIndependently verified blind Pan-Tompkins QRS sensitivity/PPV across 109,966 beats (+-150 ms) and blind DS2 330-epoch AUROC + 49,689-beat VEB sensitivity/specificity.
Raw verifier output (3 values)48-rec QRS Sens=99.33%, PPV=99.61% (n=109966); DS2 epoch AUROC=0.9781 vs RR_base=0.8625; DS2 beat Sens=96.47%, Spec=98.78%
G4PassElectrode detachment HOLD, AAMI paced quarantine & MFDS hardware gateVerified SNR < 6.0 dB automatic abstention, quarantined 4 AAMI-excluded paced records (102, 104, 107, 217), and preserved domestic patch impedance bench requirements.
Raw verifier output (3 values)paced_quarantined=4; hold_cases=1; flat_metric_errors=0

Preserved limitations, boundaries, and HOLDs

  • Boundary Tall peaked P waves (record 108) and ventricular flutter (record 207) challenge single-band QRS detection
    Across all 48 raw 360 Hz records (109966 beats), blind Pan-Tompkins achieves 99.33% sensitivity (99.28%-99.37%) and 99.61% PPV, with residual false alarms concentrated in giant P-wave noise bursts and non-QRS ventricular flutter oscillations.
  • Hold Skeletal EMG & electrode pop below 6.0 dB SNR require mandatory patch HOLD
    When dry/hydrogel patch detachment lowers SNR to 3.8 dB (< 6.0 dB), bandpass energy mimics polymorphic ventricular tachycardia; automatic HOLD suppresses false bedside alarms until skin contact recovers.
  • External AAMI paced quarantine & domestic wearable patch impedance front-end trial gate
    Following ANSI/AAMI EC57, 4 paced records (102, 104, 107, 217) remain quarantined from sinus/VEB scoring; MFDS Class II/III SaMD clearance requires hardware lead-off impedance coupling and Korean ambulatory Holter clinical validation.

Unexecuted external statutory steps & dossier checklist

  • ANSI/AAMI EC57 beat & rhythm performance reporting for MFDS review
  • Wearable patch front-end impedance & motion bench testing (unexecuted)
  • All 48/48 MIT-BIH 360 Hz .dat binary waveform decoding verification
  • Blind Pan-Tompkins QRS detection sensitivity & PPV against .atr truth
  • Patient-disjoint Chazal DS1 train -> DS2 test beat/record evaluation
  • Low-SNR electrode contact noise automatic HOLD abstention gate

4. Frozen input SHA-256 provenance and internal replay CLI

Public provenance JSON
Input archive / manifestRecordsSHA-256
PhysioNet MIT-BIH Arrhythmia Database RECORDS Manifest48fcdca7ead9fc93f612f7e025029241cb6429ba2fcd05327b661bdc6b26fbcb57
PhysioNet MIT-BIH 48 Complete Records (48 .hea + 48 .atr + 48 Format-212 .dat)14470be629ece6db55de63ba42a4545bc58224e97bbb14776e17b6af6c7f4e21688
Internal maintainer CLI (local repo .venv only): ./scripts/check