Research classification from fetal-heart-rate recordings
Runs the evaluation input checks, preprocessing and model on 4 Hz recordings. Incomplete or poor-quality inputs receive no score. This is research classification of cord-blood acidemia; clinical decisions remain on hold.
Compare measured FHR (solid blue, CTU-UHB 4 Hz) with intervillous pO2 estimated by an ODE model (dashed amber, unmeasured, drawn when available) at cutoffs counted in minutes before the recording end. The pO2 curve is a model output, not a sensor reading. Measured FHR after the cutoff stays solid at lower opacity on a gray band and is excluded from model input.
Frozen-cohort evaluation record S-PUB
These are frozen-cohort evaluation records. The evaluated-model form uses those preprocessing steps and weights. These metrics do not establish the scope of separate mathematical calculators or the full research scope.
CTU-UHB record-end umbilical acidemia research classification AUROC (pH < 7.15)0.7582 AUROCTarget: 552 records; 4 Hz waveforms and four stable covariates; six untimed clinical-event covariates excluded; record-end classification; >35% dropout HOLD
95% CI & denominator[0.6264, 0.8724]n=124
Baseline comparison0.497 AUROCAntenatal Maternal Age Baseline
Research classification of cord-blood pH < 7.15 using 4 Hz fetal-heart-rate and uterine-activity recordings. Runs the evaluation preprocessing and weights; it does not establish safety or make clinical decisions.
Enter data and run to see the score, model identity and evaluation evidence.
1. Supplied-input calculation and verification
Run after entering values to create a new calculation and hash. Editing clears the previous result.
Computes dropout, variability and deceleration statistics from a 4 Hz trace. This basic statistics calculator does not provide an acidemia probability. The evaluated cohort classifier runs in the separate form on the fetal-heart-rate track page.
Input parameters
POST /api/run/ctg
Ready
POST /api/run/ctg
Enter values and run. Examples are labeled. A numerical PASS does not establish clinical validity or full capability.
Full prefix PRSA/Spectral/Entropy acidemia AUROC (pH < 7.15)
0.7531 AUROC
Decodes all 552 binary Format-16 4 Hz FHR/UC waveforms to extract a 3.75-second (1/16-min) epoch baseline and STV proxy (adapted from the antepartum Dawes-Redman epoch formula; not intrapartum FIGO clinical criteria), LTV, late deceleration lag/area, uterine tachysystole, and coupled uteroplacental PO2 ODE hypoxia states (model-computed, not measured) with gestational weeks, gravidity, parity and maternal age only. Undated clinical-event covariates are excluded; no prospective time-horizon validation is claimed.
Audited offline reference cases
PASS means the input and signal-quality computation gates passed for that record. It is not a clinical normal or negative verdict. HOLD means automated scoring was withheld.
PassCompute gate only, not clinical normalfetal-case-01-reactive-term
Case 01 · Term intrapartum record (cord pH 7.37, score 0.016)
Stable baseline FHR with preserved short-term variability on the 3.75-second (1/16-min) epoch baseline and STV proxy (adapted from the antepartum Dawes-Redman epoch formula; not intrapartum FIGO clinical criteria), minimal signal loss, and umbilical arterial pH in the non-acidemic range.
Baseline FHR (bpm)
156.8
Late deceleration lag (s)
22.4
Long-term variability (bpm)
10.7
Research classification score
0.016
Short-term variability (ms)
5.61
Signal loss (%)
1.1
Umbilical arterial pH
7.37
3. Solver-free independent audit gates (G1-G4)
solverFree = True
Gate
Status
Specification & verification detail
Observed summary
G1
Pass
552/552 CTU-UHB header & 4 Hz waveform SHA-256 + split lockVerified all 552 .hea clinical headers and all 552 Format-16 4 Hz .dat binary waveforms on disk with zero train/val/test delivery overlap.
Forbidden Outcome/Covariate exclusion & uteroplacental O2 conservationOutcome labels, stage-II timing and six untimed clinical-event covariates are excluded; frozen inference matches all stored predictions and RK4 O2 conservation is checked (<1e-6).
Raw verifier output (4 values)leaked_features=0; max_O2_residual=2.50e-07; ODE_pH(normal=7.3011, tachy=6.85, preeclampsia=6.85)
G3
Pass
Solver-free locked-test umbilical acidemia AUROC & 4 Hz Spearman auditIndependently recomputed eligible test AUROC for pH < 7.15 and pH < 7.10 versus maternal-age baseline, plus 493-record deceleration-area vs cord pH Spearman rho under identical fitting/evaluation/serving rules.
>35% Doppler signal-dropout HOLD gate & statutory OB/GYN boundariesIdentical input and quality rules abstained on 59/552 records (12/136 in test). Missing covariates, constant channels and unusable signals receive no score during fitting, evaluation or serving.
Raw verifier output (2 values)cohort_HOLD=59/552 (10.7%, 95% CI [8.4%, 13.5%]); test_HOLD=12/136
Preserved limitations, boundaries, and HOLDs
BoundaryFour stable covariates and record-end 4 Hz waveform classification Excluding outcome labels, delivery-stage fields and six untimed clinical-event covariates yields record-end test AUROC 0.7582 for pH < 7.15 and 0.8385 for the secondary endpoint pH < 7.10 across 124 QC-passing deliveries (versus antenatal maternal-age baseline 0.4970).
BoundaryDelivery-record unit and retrospective classification scope The split and bootstrap unit is one CTG delivery record. Maternal linkage across different deliveries is unavailable. The study does not establish mother-level independence, prospective lead time, or calibrated individual clinical risk.
HoldSevere Doppler signal loss (>35%) masks late decelerations without mandatory HOLD The identical fitting/evaluation/serving contract abstains on 59/552 records. No normal default features or probability are manufactured for missing covariates, constant channels or unusable signals.
ExternalDomestic delivery-ward IRB chart concordance and internal conflict-of-interest disclosure Commercial MFDS Obstetric SaMD submission requires multi-center Korean delivery-ward IRB chart concordance, IEC 62366-1 alarm-fatigue human-factors validation; under RISCON Labs internal rules, specialist advisory review also follows a written conflict-of-interest disclosure.