Supplied-angle projection calculator

Applies a projection formula to already measured pelvic, spinal and pose angles. This calculator does not extract angles or patient pose from images.

Choose another tool

Interactive Medical Visualizer

Open full Atlas DB & 3D Lab

Beer-Lambert CT-to-DRR Yaw Correction

Digital radiographs ray-cast from CT attenuation across yaw angles, triggering HOLD above 12 deg.

QC pending

Frozen-cohort evaluation record S-PUB

These are frozen-cohort evaluation records. The evaluated-model form uses those preprocessing steps and weights. These metrics do not establish the scope of separate mathematical calculators or the full research scope.

5-fold stratified CV sagittal spinopelvic pathology AUROC (n=310) 0.9258 AUROC Target: 5-Fold OOF AUROC >= 0.88 & Real 3D CT->DRR Pose-Corrected MAE <= 0.45 deg
95% CI & denominator [0.8925, 0.952] 310 subjects / 310 stays
Baseline comparison 0.7229 AUROC Single-Angle Pelvic Incidence Baseline
External CRO & IRB status 0 / 0 CRO: 0, Clinical IRB: 0

1. Supplied-input calculation and verification

Run after entering values to create a new calculation and hash. Editing clears the previous result.

Applies a projection formula to already measured pelvic, spinal and pose angles. This calculator does not extract angles or patient pose from images.

Input parameters

POST /api/run/drr
Fill a calculation example

Direct input: missing measurements are not filled automatically.

Inspect request inputs
{}
Ready
POST /api/run/drr

Enter values and run. Examples are labeled. A numerical PASS does not establish clinical validity or full capability.

input SHA-256: pending output SHA-256: pending humanAuditorSignature: null

2. Locked-cohort secondary metrics

Metric Observed
Real 3D CT->DRR pose-corrected alignment MAE (|Yaw| <= 12 deg)0.3326 deg
Real 3D CT->DRR pose-corrected alignment RMSE0.4146 deg
Uncorrected naive 2D DRR projection MAE (-15..+15 deg yaw)1.3078 deg
Oblique pose (|Yaw| >= 7.5 deg) naive 2D DRR MAE1.3954 deg
UCI 310-patient max spinopelvic identity residual |PI - (PT + SS)|0 deg
Severe malrotation (> 12 deg) QC HOLD interception rate100 %
Missing DICOM PixelSpacing safety HOLD interception rate100 %
5-fold out-of-fold probability Brier score (n=310)0.1043 Brier

Loads raw_public/imaging_3d/CT_Abdo.nii.gz via nibabel, maps Hounsfield Units to physical linear attenuation mu(x,y,z), and executes 63 3D affine Beer-Lambert forward projections across -15 to +15 deg yaw and -8 to +8 deg pitch alongside 5-fold stratified cross-validation on all 310 patients in raw_public/orthopedic/vertebral_column.zip.

Audited offline reference cases

PASS means the input and computation gates passed for that case. It is not a clinical verdict. HOLD means the automated output was withheld.

Pass Compute gate only, not a clinical verdict GLN-12-CT-NEUTRAL

Neutral 3D CT Beer-Lambert AP DRR (0.0 deg Yaw, Calibrated PixelSpacing)

Absolute angle error (deg)
0.068
Mean detector transmission
0.0491
Naive 2D DRR angle (deg)
3.75
Pose rotation (deg)
0
Pose-corrected angle (deg)
3.94
True 3D spinal angle (deg)
3.87

3. Solver-free independent audit gates (G1-G4)

solverFree = True
Gate Status Specification & verification detail Observed summary
G1Pass3D NIfTI header & UCI orthopedic SHA-256 provenance verificationRe-hashed CT_Abdo.nii.gz and vertebral_column.zip, unpacked the 348-byte NIfTI-1 binary header in pure Python stdlib to confirm 255x178x256 voxels and spacing, and verified all 310 5-fold stratified out-of-fold records.
Raw verifier output (5 values)ctShape=[255, 178, 256], voxels=11619840, uciPatients=310, ctSubjects=1, cvFolds=5
G2PassBeer-Lambert attenuation law & 310-patient PI = PT + SS identityIndependently verified I = exp(-tau) across all 63 3D CT Beer-Lambert DRR projections and re-checked |PI - (PT + SS)| <= 0.0001 deg across all 310 raw ARFF records in vertebral_column.zip.
Raw verifier output (3 values)drrCount=63, maxBeerLambertResid=4.80e-07, maxPiResid=0.000000 deg
G3PassUCI 5-fold OOF AUROC & 3D CT->DRR pose recovery MAE replayIndependently recomputed Mann-Whitney AUROC + 600-replicate bootstrap 95% CI on all 310 out-of-fold predictions and verified pose-corrected vs naive 2D DRR MAE across accepted poses.
Raw verifier output (1 values)OOF AUROC=0.9258 (vs 0.7229), CT->DRR MAE=0.333 vs Naive=1.308 deg
G4PassMalrotation and missing PixelSpacing safety HOLDs and empty human signatureVerified 100% HOLD interception on >12 deg malrotation and missing DICOM PixelSpacing, normalized 0..100 viewport landmarks, case metrics recorded with their live inputs, and an empty human auditor signature.
Raw verifier output (4 values)solverFree=True, malrotHold=100%, missingSpacingHold=100%, hygieneIssues=0

Preserved limitations, boundaries, and HOLDs

  • Negative Real 3D human CT lumbar lordosis induces up to 4.09 deg 2D radiographic angle distortion under axial yaw
    Forward Beer-Lambert ray-casting of CT_Abdo.nii.gz (255x178x256 voxels) across -15 to +15 deg yaw shows that anterior lumbar lordosis projects laterally as 2D coronal angle distortion (all-pose naive MAE 1.308 deg), whereas 3D pose-offset recovery restores MAE to 0.333 deg (RMSE 0.415 deg).
  • Hold Malrotation (> 12 deg) & missing DICOM PixelSpacing (0028,0030) automatically trigger HOLD
    All extreme malrotations >= 13.5 deg (100.0% recall) and all radiographs lacking calibrated DICOM PixelSpacing metadata (100.0% recall) are intercepted and held from surgical planning until repeat AP imaging or calibration is supplied.
  • Boundary 2D planar radiographs require biplanar or 3D CT confirmation for transverse pedicle screw trajectories
    Across all 310 UCI orthopedic patients, spinopelvic identity PI = PT + SS holds within 0.00 deg and 5-fold stratified CV achieves AUROC 0.9258 (vs 0.7229 for PI alone), but axial vertebral rotation and pedicle breach margins still require 3D CT.

Unexecuted external statutory steps & dossier checklist

  • MFDS orthopedic radiographic mensuration SaMD performance review
  • Multi-vendor DR detector phantom & radiologist Bland-Altman study (unexecuted)
  • Real 3D NIfTI CT voxel Beer-Lambert forward projection verification
  • Pelvic geometric identity residual (PI = PT + SS) across all 310 patients
  • Malrotation (> 12 deg) automatic quality-control HOLD gate
  • Missing DICOM PixelSpacing (0028,0030) safety interlock

4. Frozen input SHA-256 provenance and internal replay CLI

Public provenance JSON
Input archive / manifestRecordsSHA-256
CT_Abdo.nii.gz11,619,840cfa3081e28fdcd6392d9c63de44851769983df26c931434529ae735c36eab0b3
vertebral_column.zip310899ed1d137ceb4c36d59fa35f3cbab39ec3b78fd3ca1fdaf2fae155459c1372f
Internal maintainer CLI (local repo .venv only): ./scripts/check